Vietnamese Chinese (Traditional) English Japanese Korean

Thiết bị làm mát SMC - 1

Air Cooled Aftercooler HAA

 

Series/CAD Applicable compressor Air flow capacity L/min (ANR)
HAA 7.5 to 37 kW 1000 to 5700
Features

Can cool high temperature compressed air from compressors down to 40ºC or less and efficiently remove moisture from the air.

Cooling equipment is not required for this air cooled type.

Maintenance is easy and the running cost is reasonable since this is free from concerns such as water supply cut-off or freezing.

 

Water Cooled Aftercooler HAW

 

Series/CAD Applicable compressor Air flow capacity L/min (ANR)
HAW 2.2 to 110 kW 300 to 18000
Features

Can cool high temperature compressed air from compressors down to 40ºC or less and efficiently remove moisture from the air.

Stable operation is possible even in an environment with a hightemperature, high moisture and heavy foreign particles for this water cooled type.

 

Air Tank AT

 

Series/CAD Port size Capacity (L)
AT 1/2 to 4B flange 100 to 3000
Features

Accumulates the compressed air from compressors, also prevents it from being pulsated, and cools it.

 

Air Tank VBAT

 

Series/CAD Port size Tank capacity (L)
VBAT 3/8,1/2,3/4 5,10,20,38
Features

Compact air tank that can be directly connected with a regulator.

Can be used as an independent tank.

With a safety valve port. (Optional)

 

Refrigerated Air Dryer IDF/IDU

 

Series/CAD Applicable compressor Air flow capacity m3/min (ANR)
50 Hz 60 Hz
IDF1E to 75E 0.75 to 75 kW 0.10 to 11.0 0.12 to 12.4
IDF120D to 240D 120 to 240 kW 20.0 to 43.0 23.0 to 50.0
IDF370B 370 kW 54.0 65.0
IDU3E to 75E 2.2 to 75 kW 0.32 to 11.0 0.37 to 12.5
Features

Increases the air flow rate by a maximum of 40%*. (SMC comparison)

Reduces the power consumption by a maximum of 40%*. (SMC comparison)

Refrigerant:

R134a (HFC) [IDF1E to 15E/IDU3E to 15E]
R407C (HFC) [IDF22E to 240D/IDU22E to 75E]

Improved corrosion resistance with the use of a stainless steel, plate type heat changer. (IDF4E to 75E/IDU3E to 75E)

 

Refrigerated Air Dryer / Large Size Series IDFxF

 

Series/CAD Applicable compressor Air flow capacity m3/min (ANR)
50 Hz 60 Hz
IDF100F 100kW 16 18.8
IDF120F 125kW 20.1 23.7
IDF150F 150kW 25 30
Features

Tolerant of high temperature environment (Ambient temperature 45℃ , Inlet air temperature 60℃)

Exhaust heat reduced by 25%

Air-cooled type and water-cooled type are available.

Stainless steel heat exchanger

Refrigerant R407C (HFC)

 

Refrigerated Air Dryer/For Use in Europe, Asia, and Oceania IDFAxE

 

Series/CAD Air flow capacity m3/h (ANR) Applicable standard
Outlet air pressure dew point
3ºC 7ºC 10ºC
IDFA3E to 75E 12 to 660 15 to 720 17 to 822 CE
Features

EC Directive compliant (with CE marking)

Power supply voltage: Single-phase 230 VAC (50 Hz)

Refrigerant: R134a (HFC), R407C (HFC); Coefficient of destruction for ozone is zero.

Improved corrosion resistance with the use of stainless steel, plate type heat changer (IDFA4E to 75E)

 

Refrigerated Air Dryer / Large Size Series / For Use in Europe, Asia and Oceania IDFAxF

 

Series/CAD Outlet air pressure dew point Air flow capacity m3/h (ANR) Applicable standard
For use in Asia and Oceania IDFA100F-38 10℃ 960 CE
IDFA125F-38 1210
IDFA150F-38 1500
For use in Europe IDFA100F-40 3℃ 860
IDFA125F-40 1100
IDFA150F-40 1340
Features

Tolerant of high temperature environment. (Ambient temperature 45 ℃ at max., Inlet air temperature 60℃ at max.)

Exhaust heat reduced by 25% at max.

Power supply voltage : Three-phase 380 VAC (For Asia and Oceania), Three-phase 400 VAC (For Europe)

Employs a heat exchanger made of high corrosion-resistant stainless steel.

Refrigerant R407C (HFC)

 

Refrigerated Air Dryer/For Use in Europe, Asia, and Oceania IDFAxE

 

Series/CAD Air flow capacity m3/h (ANR) Applicable standard
Outlet air pressure dew point
37ºF (2.8ºC) 45ºF (7.2ºC) 50ºF (10ºC)
IDFB3E to 75E 10 (17) to 300 (510) 11 (19) to 353 (600) 12 (20) to 406 (690) UL, CSA
Features
  • UL certified product
  • Power supply voltage: Single-phase 115 VAC (60 Hz), 230 VAC (60 Hz), three-phase 460 VAC (60Hz)
  • Refrigerant: R134a (HFC), R407C (HFC), Coefficient of destruction for ozone is zero.
  • Improved corrosion resistance with the use of stainless steel, plate type heat changer (IDFB4E to 75E)

Tư vấn khách hàng

Tel 1 : 0918356797/zalo
Mr Tùng
Tel 2 : 0968 530 579/zalo
Mr Huynh
Tel 3 : 0917 970 997/zalo
Mr Huynh
Tel 4 : 0915356797/zalo
Mr Trúc

Facebook LikeBox