Electro-Pneumatic Regulator ITV
Series/CAD | Port size | Set pressure (MPa) |
ITV0000 | Built-in One-touch fitting φ4,φ5/32 |
0.001 to 0.1 0.001 to 0.5 0.001 to 0.9 -1 to -100kPa |
ITV1000 | 1/8,1/4 | 0.005 to 0.1 0.005 to 0.5 0.005 to 0.9 |
ITV2000 | 1/4,3/8 | |
ITV3000 | 1/4,3/8,1/2 | |
Features |
Stepless control of air pressure in proportion to electric signals Sensitivity: 0.2 kPa (100 kPa specification) Linearity: ±1% or less (F.S.) Hysteresis: 0.5% or less (F.S.) Communication: CC-Link, DeviceNetTM, PROFIBUS DP, RS-232C |
Electronic Vacuum Regulator ITV
Series/CAD | Port size | Set pressure (MPa) |
ITV209x | 1/4 | -1.3 to -80 |
Features |
Stepless control of vacuum pressure in proportion to electric signals Communication: CC-Link, DeviceNetTM, PROFIBUS DP, RS-232C |
5.0 MPa Maximum Supply Pressure - High Pressure Electro-Pneumatic Regulator ITVX
Series/CAD | Port size | Set pressure (MPa) |
ITVX | 3/8 | 0.01 to 3.0 |
Features |
Stepless control of air pressure proportional to an electrical signal Maximum supply pressure: 5.0 MPa Set pressure range: 0.01 to 3.0 MPa Maximum flow rate: 3000 L/min[ANR] Fluid: Air, N2, O2, Ar Wetted parts: Fluorine grease |
Controller for Electro-Pneumatic Regulator IC
Series/CAD | Features |
IC |
Can be mainly used integrated with the ITV0000 series without a display function. Converts digital input signal into analog output signal 10 bit parallel input signal (maximum). Pressure setting of 210 = 1024 points possible. 4 point preset output Applicable in the programming function with up to 20 steps. |
Compact Proportional Solenoid Valve PVQ
Series/CAD | Port size | Set pressure (MPa) |
PVQ | 0 to 5 0 to 6 0 to 75 0 to 100 |
Air, inert gas |
Features |
Stepless control of flow rate in proportion to current. Repeatability: 3% or less Hysteresis: 10% or less |
Electro-Pneumatic Proportional Valve VEF/VEP
Series/CAD | Port size |
VEF/VEP | 1/4,3/8,1/2 |
Features |
Stepless control of air flow or pressure by use of electric signals Press-die cushions Pressure control of welding machine and low pressure casting Multi-stage speed control of air cylinder and rotation control of air motor |
5 Port Electro-Pneumatic Proportional Valve VER
Series/CAD | Port size | Set pressure (MPa) |
VER2000·4000 | 1/4,3/8,1/2 | 0.1 to 0.9 |
Features |
Stepless control of cylinder and applied pressure Applicable cylinder φ25 to φ125 Available for exhaust throttle and B port pressure regulation. |
Power Amplifier for Electro-Pneumatic Proportional Valve VEA
Series/CAD | Features |
VEA250 |
Dedicated amplifier for driving an electro-pneumatic proportional valve Low current command signal High dither effect Stabilizing the performance of the electro-pneumatic proportional valve |
VEA251 | |
VEA252 |
E-P HYREG® VY1
Series/CAD | Port size | Set pressure (MPa) |
VY1 | M5 x 8 1/8,1/4,3/8,1/2,3/4,1,11/4,11/2,2 |
0.05 to Supply pressure |
Features |
Stepless control of pressure by use of electric signals Thrust control of cylinder Flow control of nozzle Pressure control of tank |
Booster Regulator VBA
Series/CAD | Port size | Set pressure (MPa) |
VBA | 1/4,3/8,1/2 | VBA10A: 0.2 to 2.0 VBA2xA: 0.2 to 1.0 VBA4xA: 0.2 to 1.0 VBA43A: 0.2 to 1.6 |
Features |
Can increase the factory air a maximum of 200 %, power supply not required. Possible to get a maximum of double pressure by connecting air with a factory line. (VBA11A: maximum 4 times) Space-saving type that directly connects air tanks and booster regulators. |
Air Tank VBAT
Series/CAD | Port size | Set pressure (MPa) |
VBAT | 3/8,1/2,3/4 | 5,10,20,38 |
Features |
Compact air tank that can be directly connected with a regulator. Can be used as an independent tank. With a safety valve port. (Optional) |
Pressure Control Valve AP100
Series/CAD | Port size | Set pressure (MPa) |
AP100 | 1/8,1/4 | 0.05 to 0.69 MPa |
Features |
|